Observation Ids

Here you will find a complete list of observation ids that are available from our Observations endpoint

ID Observation Info Value Type Response
1 SELF TEST RESULT PASSED or error codes  String
2 SELF TEST DETAILS JSON with details from self-tes  String JSON
10 WIFI EVENT Wifi event  Integer Event Easee Internal usage
11 CHARGER OFFLINE REASON Enum describing why charger is offline  Integer
15 LOCAL PRE AUTHORIZE ENABLED Preauthorize with whitelist enabled. Readback on setting Boolean Event
16 LOCAL AUTHORIZE OFFLINE ENABLED Allow offline charging for whitelisted RFID token. Readback on setting Boolean Event
17 ALLOW OFFLINE TX FOR UNKNOWN ID Allow offline charging for all RFID tokens. Readback on setting Boolean Event
18 ERRATIC EVMAX TOGGLES 0 == erratic checking disabled, otherwise the number of toggles between states Charging and Charging Complate that will trigger an error  Integer
19 BACKPLATE TYPE erratic checking type of backplate, type =0 corrsponds to comercialcharger, type =1 corrsponds to testing charger  Integer
20 SITE STRUCTURE checking site structure and displaying address,conctac info, installer, owner etc  String JSON
21 DETECTED POWER GRID TYPE Detected power grid type according to PowerGridType table  Integer Boot
22 Circuit Max Current P1 Circuit max current in Ampers of Phase 1 Integer Event
23 Circuit Max Current P2 Circuit max current in Ampers of Phase 2 Integer Event
24 Circuit Max Current P3 Circuit max current in Ampers of Phase 3 Integer Event
26 Site ID String Site ID as a string  String
27 Site ID Numeric Site ID as a numeric  Integer
28 RFID TIMEOUT AUTH Timeout set for authentication for when Authentication == True  Integer
30 LOCK CABLE PERMANENTLY Lock type2 cable permanently  Boolean
31 IS ENABLED Set true to enable charger, false disables charger  Boolean
32 TEMPERATURE MONITOR STATE Retrieves temperature of the charger  Integer
36 WIFI SSID Network name charger/s are connected to  String
38 PHASE MODE erratic showing what phase mode is the charger connected to, phase mode ==1 --> one phase, phase mode==3 --> 3 phase  Integer
40 LED STRIP BRIGHTNESS erratic showing in integer the LED brightness  Integer Boot
41 LOCAL AUTHORIZATION REQUIRED Local RFID authorization is required for charging  Boolean Event User Options
42 AUTHORIZATION REQUIRED Authorization is required for charging Boolean
43 REMOTE START REQUIRED Remote start required flag Boolean Event
44 SMART BUTTON ENABLED Smart button is enabled Boolean
45 OFFLINE CHARGING MODE Charger behaviour when offline Integer
46 LEDMODE Charger LED mode Integer Event
47 MAX CHARGER CURRENT Max current this charger is allowed to offer to car (A). Non volatile.  Double
48 DYNAMIC CHARGER CURRENT Max current this charger is allowed to offer to car (A). Volatile Double
50 MAX CURRENT OFFLINE FALLBACK P1 Maximum circuit current P1 when offline Integer Event
51 MAX CURRENT OFFLINE FALLBACK P2 Maximum circuit current P2 when offline Integer Event
52 MAX CURRENT OFFLINE FALLBACK P3 Maximum circuit current P3 when offline  Integer Event
54 RELEASE CABLE AT POWER OFF If set to Yes, cable is released when power off. If set to No, cable not released  String Event
62 CHARGING SCHEDULE Charging schedule  String Json
65 PAIRED EQUALIZER Paired equalizer details String
69 PAIRED USER IDTOKEN Observed user token when charger put in RFID pairing mode String Event
70 Circuit Total Allocated Phase Conductor Current L1 Circuit Total Allocated Phase Conductor Current L1 Integer Boot
71 Circuit Total Allocated Phase Conductor Current L2 Circuit Total Allocated Phase Conductor Current L2 Integer Boot
72 Circuit Total Allocated Phase Conductor Current L3 Circuit Total Allocated Phase Conductor Current L3 Integer Boot
73 Circuit Total Phase Conductor Current L1 Circuit Total Phase Conductor Current L1 Integer Boot
74 Circuit Total Phase Conductor Current L2 Circuit Total Phase Conductor Current L2 Integer Boot
75 Circuit Total Phase Conductor Current L3 Circuit Total Phase Conductor Current L3 Integer Boot
76 NUMBER OF CARS CONNECTED Number of cars connected to this circuit Integer
77 NUMBER OF CARS CHARGING Number of cars currently charging Integer
78 NUMBER OF CARS IN QUEUE Number of cars currently in queue, waiting to be allocated power Integer
79 NUMBER OF CARS FULLY CHARGED Number of cars that appear to be fully charged  Integer
80 SOFTWARE RELEASE Firmware of charger  Integer Boot
81 ICCID ICCID number   Integer Boot
84 Mobile Network Operator Name of mobile network operator String Event
89 REBOOT REASON Reason of reboot. Bitmask of flags. Integer
96 REASON FOR NO CURRENT Enum describing why a charger with a car connected is not offering current to the car Integer
97 LOAD BALANCING NUMBER OF CONNECTED CHARGERS Number of connected chargers in the load balancing. Including the master. Sent from Master only.  Integer
98 UDP NUM OF CONNECTED NODES Number of chargers connected to master through UDP and WIFI  Integer
99 Local Connection Secondarychargers only. Current connection to master, 0 = None, 1= Radio, 2 = WIFI UDP, 3 = Radio and WIFI UDP. String Boot
100 PILOT MODE Pilot Mode Letter (A-F)  String Event
102 SMART CHARGING Smart charging state enabled by capacitive touch button  Boolean Event
103 CABLE LOCKED Cable lock state  Boolean Event
104 CABLE RATING Cable rating read (Amperes) Double Event
107 BACKPLATE ID Backplate id String Boot
108 USER IDTOKEN REVERSED User ID token string from RFID reading (NB! Must reverse these strings)  String Event
109 CHARGER OP MODE Charger operation mode according to charger mode table  Integer Event
110 OUTPUT PHASE Active output phase(s) to EV according to output phase type table.  Integer Event
111 Dynamic Circuit Current P1 Dynamic Circuit current in P1 in Amps  Integer Event
112 Dynamic Circuit Current P2 ADynamic Circuit current in P2 in Amps  Integer Event
113 Dynamic Circuit Current P3 Dynamic Circuit current in P3 in Amps  Integer Event
114 Output Current Available current signaled to car with pilot tone in Amps  Integer Boot Easee Internal usage
115 Derated Current Available current after derating  Double Event Easee Internal usage
116 DERATING ACTIVE Available current is limited by the charger due to high temperature Boolean Event
118 Error String Descriptive Error String   String Event Easee Internal usage
119 ERROR CODE Error code according to error code table [event] [Integer]  Integer Event
120 TOTAL POWER Total power (kW) Double Telemetry
121 SESSION ENERGY Session accumulated energy (kWh)  Double Telemetry
122 ENERGY PER HOUR Accumulated energy per hour (kWh) Double Event
123 LEGACY EV STATUS 0 = not legacy ev, 1 = legacy ev detected, 2 = reviving ev Integer Event Easee Internal usage
124 LIFETIME ENERGY Accumulated energy in the lifetime of the charger (kWh) Double
125 LIFETIME RELAY SWITCHES Total number of relay switches in the lifetime of the charger (irrespective of the number of phases used) Integer Easee Internal usage
126 LIFETIME HOURS Total number of hours in operation Integer Easee Internal usage
128 USER IDTOKEN User ID token string from RFID reading String Event
129 CHARGING SESSION Charging sessions String Event Json
130 CELL RSSI Cellular signal strength (dBm) Integer Telemetry
131 CELL RAT Cellular radio access technology according to RAT table Integer Event
132 WI FI RSSI WiFi signal strength (dBm) Integer Telemetry
133 CELL ADDRESS IP address assigned by cellular network Sring Event Easee Internal usage
134 WIFI ADDRESS IP address assigned by WiFi network Sring Event Easee Internal usage
136 LOCAL RSSI Local radio signal strength (dBm) Integer Telemetry
138 LOCAL TX POWER Local radio transmission power (dBm)  Integer Telemetry
139 LOCAL STATE Local radio state String Event
141 CURRENT CONNECTION Radio access technology in use: 0 = cellular, 1 = wifi Integer Event
146 LOCAL NODE TYPE erratic=0-Unconfigured, 1-Master, 2-Extender, 3-End devicet Integer Event
149 LOCAL PARENT ADDR OR NUM OF NODES If master-Number of secondary connected, If secondary- Address parent Integer Event Easee Internal usage
150 TEMP MAX Maximum temperature for all sensors Double Event
152 TEMP INPUT T2 Temperature at input T2 Double Event
153 TEMP INPUT T3 Temperature at input T3 Double Event
154 TEMP INPUT T4 Temperature at input T4 Double Event
155 TEMP INPUT T5 Temperature at input T5 Double Event
160 TEMP OUTPUT N Temperature at type 2 connector plug for N Double Event
161 TEMP OUTPUT L1 Temperature at type 2 connector plug for L1 Double Event
162 TEMP OUTPUT L2 Temperature at type 2 connector plug for L2 Double Event
163 TEMP OUTPUT L3 Temperature at type 2 connector plug for L3 Double Event
170 TEMP AMBIENT Ambient temperature [Celsius] Double Event
172 INT REL HUMIDITY Internal relative humidity Double Event
173 BACKPLATE LOCKED Back plate confirmed locked Double Event
182 INT CURRENT T2 Calculated current RMS for input T2 Double Event
183 INT CURRENT T3 Calculated current RMS for input T3 Double Event
184 INT CURRENT T4 Calculated current RMS for input T4 Double Event
185 INT CURRENT T5 Calculated current RMS for input T5 Double Event
190 IN VOLT T1T2 Input voltage RMS between T1 and T2 Double Event
191 IN VOLT T1T3 Input voltage RMS between T1 and T3 Double Event
192 IN VOLT T1T4 Input voltage RMS between T1 and T4 Double Event
193 IN VOLT T1T5 Input voltage RMS between T1 and T5 Double Event
194 IN VOLT T2T3 Input voltage RMS between T2 and T3 Double Event
195 IN VOLT T2T4 Input voltage RMS between T2 and T4 Double Event
196 IN VOLT T2T5 Input voltage RMS between T2 and T5 Double Event
197 IN VOLT T3T4 Input voltage RMS between T3 and T4 Double Event
198 IN VOLT T3T5 Input voltage RMS between T3 and T5 Double Event
199 IN VOLT T4T5 Input voltage RMS between T4 and T5 Double Event
202 OUT VOLT PIN 1&2 Output voltage RMS between type 2 pin 1 and 2 Double Event
203 OUT VOLT PIN 1&3 Output voltage RMS between type 2 pin 1 and 3 Double Event
204 OUT VOLT PIN 1&4 Output voltage RMS between type 2 pin 1 and 4 Double Event
205 OUT VOLT PIN 1&5 Output voltage RMS between type 2 pin 1 and 5 Double Event
206 OUT VOLT PIN 2&3 Output voltage RMS between type 2 pin 2 and 3 Double Event
223 CHARGE SESSION START Last session details String JSON
230 EQ AVAILABLE CURRENT P1 Available current for charging on P1 according to Equalizer Double
231 EQ AVAILABLE CURRENT P2 Available current for charging on P2 according to Equalizer Double
232 EQ AVAILABLE CURRENT P3 Available current for charging on P3 according to Equalizer Double
250 CONNECTED TO CLOUD If charger connected to cloud or not BOOLEAN Boot
251 CLOUD DISCONNECT REASON Reason why charger disconnected from cloud String Boot Easee Internal usage